INPUT |
|
Input Phase |
Single-Phase |
Rated input current (Maximum Load) |
4.64A |
Nominal Input Voltage(s) Supported |
220V AC; 230V AC; 240V AC |
UPS Input Connection Type |
CEE 7/7 Schuko |
UPS Input Cord Length (ft.) |
4.92126 |
Input Frequency |
50/60Hz Automatic frequency selection |
OUTPUT |
|
Output Capacity (VA) |
1000 |
Output Capacity (kVA) |
1 |
Output Capacity (Watts) |
600 |
Output Capacity (kW) |
0.6 |
Output Capacity Details |
LINE MODE: 110% (±10%) UPS goes to FAULT MODE within 5 minutes / 120% (±10%) UPS goes to FAULT MODE immediately; BATTERY MODE: 110% (±10%) UPS shutdown within 5 seconds |
Nominal Voltage Details |
230V nominal output in battery mode |
Frequency Compatibility |
50 / 60 Hz |
Frequency Compatibility Details |
Automatic frequency selection |
Output Voltage Regulation (Line Mode) |
+10%, -18% |
Output Voltage Regulation (Battery Mode) |
230V ±10% |
Output Receptacle Details |
All outlets provide UPS battery backup and Automatic Voltage Regulation |
Output AC Waveform (AC Mode) |
Sine wave |
Output AC Waveform (Battery Mode) |
PWM sine wave |
Nominal Output Voltage(s) Supported |
220V; 230V; 240V |
Output Receptacles |
(4) CEE7/7 |
BATTERY |
|
Battery Type |
Valve Regulated Lead Acid (VRLA) |
Runtime Full Load (min.) |
1 min. (600W) |
Runtime Half Load (min.) |
1.2 min. (300W) |
DC System Voltage (VDC) |
12 |
Battery Recharge Rate (Included Batteries) |
Less than 8 hours from 10% to 90% |
VOLTAGE REGULATION |
|
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 159 to 282VAC |
Overvoltage Correction |
Input voltages between 253 and 282 (±5%) are reduced by 15% |
Undervoltage Correction |
Input voltages between 159 and 207 (±5%) are boosted by 18% |
USER INTERFACE, ALERTS & CONTROLS |
|
Switches |
Lighted on/off power switch |
Audible Alarm |
Audible alarm indicator reports POWER-FAILURE, LOW-BATTERY, OVERLOAD, FAULT and BATTERY EXPIRED status (see manual) |
LED Indicators |
Lighted LED power switch indicator reports POWER-FAILURE, LOW-BATTERY, OVERLOAD, FAULT and BATTERY EXPIRED status (see manual) |
SURGE / NOISE SUPPRESSION |
|
EMI / RFI AC Noise Suppression |
Yes |
AC Suppression Joule Rating |
156 |
AC Suppression Response Time |
Instantaneous |
PHYSICAL |
|
Primary Form Factor |
Desktop |
Installation Form Factors Supported with Included Accessories |
Tower; Ultra-compact desktop; Wallmount |
Primary UPS Depth (mm) |
280 |
Primary UPS Height (mm) |
91 |
Primary UPS Width (mm) |
190 |
Shipping Dimensions (hwd / in.) |
10.20 x 5.27 x 14.25 |
UPS Power Module Dimensions (hwd, in.) |
3.58 x 7.48 x 11.02 |
UPS Power Module Weight (kg) |
5.9 |
UPS Power Module Weight (lbs.) |
13.01 |
Unit Dimensions (hwd / in.) |
3.580 x 7.480 x 11.020 |
Unit Weight (lbs.) |
13.01 |
ENVIRONMENTAL |
|
Operating Temperature Range |
32° to 104°F (0° to 40°C) |
Storage Temperature Range |
5° to 113°F (-15° to 45°C ) |
Relative Humidity |
0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) |
102.39 |
AC Mode Efficiency Rating (100% Load) |
>95% |
Audible Noise |
<40dB, 1 meter |
COMMUNICATIONS |
|
Network Management Card Description |
Network management not supported |
Communications Interface |
None |
LINE / BATTERY TRANSFER |
|
Transfer Time |
2-6 ms (typical); 10 ms (maximum) |
Low Voltage Transfer to Battery Power (Setpoint) |
159V (±5%) |
High Voltage Transfer to Battery Power (Setpoint) |
282V (±5%) |
FEATURES & SPECIFICATIONS |
|
Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
High Availability UPS Features |
Surge/noise protection |
Green Energy-Saving Features |
Greater than 95% efficiency – GREEN UPS |
Grounding Details |
Yes |
APPLICATIONS |
|
UPS Applications |
Home/Office Desktop; Audio/Video |
Eaton 230V 1000VA 600W Ultra-Compact Line-Interactive UPS – 4 Schuko Outlets Desktop/Wall-Mount
Brand :
EGP4,250.00
Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.
1 in stock
Reviews